Synthes large frag inventory.

Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 –90° 02.115.640 4 49 +90° 02.115.641 4 49 –90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes head

Synthes large frag inventory. Things To Know About Synthes large frag inventory.

The DePuy Synthes Vet Large Fragment System is part of a stainless-steel plate and screw system that merges locking screw technology with conventional plating techniques. This system contains the 4.5mm – 5.5mm implants and related instruments required for LC-DCP ®, DCP ® and LCP ® Plating. The Large Fragment System provides the most ...3. In the form creation screen, choose the "Small Frag Inventory" template from the available options. 4. Once the form is open, you will see various fields and sections to fill out. 5. Begin by entering the necessary details about the small frag inventory, such as the date, location, and any unique identifier or reference number. 6.Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 …If the screw fragment is deep or firmly seated: Screw Removal - Technique Technique Reference: R. Texhammar, C. Colton. AO ASIF Instruments and Implants.2nd ed. Berlin: Springer-Verlag, 1994. Create an opening with the Small Countersink [310.89] or Large Countersink [310.99]. 1 To remove the centering pin, the reamer tube must be removed first.

01.775.000, 01.775.000E, FGS-1000... The FIBULINK™ Syndesmosis Repair System provides the fixation of a screw with the flexibility of a suture. 1-3 This design is intended to enable precise, anatomic syndesmotic fixation, 2-5 improve tension control, 2-4,6 and reduce medial soft tissue disruption. 3,4 *.Caravana Car Sales is a leading online platform for buying and selling used vehicles. With a vast inventory of cars, trucks, and SUVs, it can be overwhelming to navigate through al...

INVENTORY CONTROL FORM 2.4 mm LCP ® Distal Radius Plate System 2.4 mm Locking Screws, self-tapping, T8 STARDRIVE TM Screwdriver Recess 2.4 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess 2.7 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess LENGTH 212.806 6 mm 212.808 8 mm 212.810 10 mm 212.812 12 mm 212.814 14 mm ...

Inventory Control Form Titanium Small Fragment Locking Compression Plate (LCP™) System 2.7 mm Cortex Screws, self-tapping LengthLength 412.101 10 mm 412.102 12 mm 412.103 14 mm 412.104 16 mm 412.105 18 mm 412.106 20 mm 412.107 22 mm 412.108 24 mm 412.109 26 mm 412.110 28 mm 412.111 30 mm 412.112 32 mm 412.113 34 mm 412.114 35 mm Inventory Control Form Modular Foot System Implants and Instruments Instruments 3 3.5 mm One-Third Tubular Plate Holes 241.344 241.355 241.366 241.388 Washer 219.98 7.0 mm Buttress Pin 201.980 1.8 mm, 30 mm Kirschner Wires 292.10 1.0 mm trocar point 292.12 1.25 mm trocar point 292.16 1.6 mm trocar point 292.20 2.0 mm trocar pointFill Synthes Dhs Inventory, Edit online. Sign, fax and printable from PC, iPad, tablet or mobile with pdfFiller Instantly. Try Now!processing of DePuy Synthes non-sterile implants, please consult the Important Information leaflet (SE_023827) or refer to: ... Reduce fracture with large reduction forceps with points. Preliminary fix it with two parallel 1.6- to 2.0-mm- ... If the fragment is correctly reduced, perform percutaneous pinning. 3. Implant removalGet the Synthes wrist fusion inventory control form accomplished. Download your updated document, export it to the cloud, print it from the editor, or share it with others through a Shareable link or as an email attachment. ... stryker wrist fusion plate 319.01 synthes synthes small frag inventory. Related forms. 18448988542. Learn more ...

Make any changes required: add text and pictures to your Synthes large frag inventory, highlight important details, erase sections of content and substitute them with new ones, and add symbols, checkmarks, and fields for filling out. Finish redacting the form. Save the modified document on your device, export it to the cloud, print it right ...

Size-specific modules. Offering surgeons the simplicity of a comprehensive plating system that addresses all small fragment surgical needs. Additionally, this system provides color-coding of instruments and trays to match plate and screw fixation options.

SYNTHES (CANADA) LTD. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 Fax: (905) 567-3185 To order: (800) 668-1119 SYNTHES (USA) 1690 Russell Road Paoli, PA 19301-1262 Telephone: (610) 647-9700 Fax: (610) 251-9056 To order: (800) 523-0322 Original Instruments and Implants of the Association Large Fragment Locking Compression Plate (LCP. TECHNIQUE GUIDE. Introduction Indications. The Synthes Locking Compression Plates—Narrow and Broad, are intended for fixation of various long bones, such as the humerus, femur and tibia. They are also for use in fixation of periprosthetic fractures, osteopenic bone, and nonunions or malunions. A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.Follow our simple steps to get your Synthes Large Frag Inventory ready quickly: Select the template from the library. Type all required information in the required fillable fields. The easy-to-use drag&drop interface makes it easy to add or move fields. Ensure everything is filled in properly, with no typos or lacking blocks.synthes.vo.llnwd.netAdditional Info. Unit of Measurement: Each. Catalog Number: 105.11. Set is comprised of an array of 4.5 mm and 6.5 mm screw types and sizes, as well as storage. CLICK HERE for a full list of set components. See close-up and descriptions of the screws included in set below. 214.034 shown on top. Catalog #. Description.6 DePuy Synthes 2.7 mm/3.5 mm LCP® Distal Fibula Plates Surgical Technique Preparation The techniques for implanting the lateral and posterolateral distal fibula plates are similar. The following describes implantation of a lateral plate. 1 Preoperative planning Required set 105.434/ Small Fragment LCP Instrument and Implant

Note: For information on fixation principles using conventional and locked plating techniques, please refer to the Synthes Large Fragment Locking Compression Plate (LCP) Technique Guide. 2 Synthes 4.5 mm LCP Medial Proximal Tibia Plates Technique Guide Available in left and right plates, in implant quality 316L stainless steel.Manage synthes large cchs inventory on any device with airSlate SignNow Android or iOS apps and elevate any document-centered operation today. How to change and eSign synthes non locking small frag inventory without breaking a sweat. Get synthes small cchs and click Get Form to get started.Get the Synthes Large Frag Inventory you need. Open it using the online editor and begin altering. Complete the blank areas; concerned parties names, places of residence and phone numbers etc. Change the blanks with smart fillable areas. Add the date and place your e-signature. Click Done after double-checking everything.increasing market shift to fragment -specific plating and using small plates as adjuncts to other means of adjunct fixation. The modular tray offers screw and plate options in 2.0 mm, 2.4 mm, and 2.7 mm. With a variety of plates to fit a multitude of trauma needs, the Mini Frag System is a keystone addition to the Arthrex Trauma lineup thatInstrument assembly. 1. Choose the matching guiding block and place it onto the plate head. Make sure that the three-point locking mech-anism is positioned on the pre-contoured reference points of the plate. 2. Insert a first LCP drill sleeve through the guiding block into the central hole (A) of the plate and tighten it.6ePuy D Synthes 3.5 mm LCP® Clavicle Hook Plates Surgical Technique Lateral Clavicle Fractures 1 Position the patient Required set 105.434 Small Fragment LCP Instrument and Implant Set, with self-tapping screws or 145.434 Small Fragment LCP Instrument and Titanium Implant Set, with self-tapping screws

Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 24 mm 214. ...

Follow our simple steps to get your Synthes Large Frag Inventory ready quickly: Select the template from the library. Type all required information in the required fillable fields. The easy-to-use drag&drop interface makes it easy to add or move fields. Ensure everything is filled in properly, with no typos or lacking blocks.The following tips can help you fill out Synthes Mini Frag Inventory quickly and easily: Open the template in the feature-rich online editing tool by clicking Get form. Complete the necessary boxes that are colored in yellow. Click the green arrow with the inscription Next to move on from one field to another.Dorsal Distal Radius Plate Surgical Technique DePuy Synthes 3. In 1958, the AO formulated four basic principles, which . 1 4 2 3. 4_Priciples_03.pdf 1 05.07.12 12:08. 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique. AO PRINCIPLES. In 1958, the AO formulated four basic principles, whichSynthes Synthes Large External Fixator Medium External Fixator Set | 01.302.602 Synthes Trochanter Stabilization Plate Instrument & Implant Set | 105.385 ... Synthes Large Fragment LCP Instrument Set | 115.401 Synthes Mini Fragment Instrument & Titanium Implant Set w/Self-Tapping Screws | 125.488Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 -90° 02.115.640 4 49 +90° 02.115.641 4 49 -90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes head9. Repeat steps 3 to 8 for all the items in the inventory until the entire list is completed. 10. Double-check the information entered to ensure accuracy and completeness. Correct any mistakes or omissions before finalizing the inventory form. 11. Save or print the completed Synforms CCHS Inventory form for record-keeping and reference purposes.Inventory Control Form Large Fragment LCP™ System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. …

Click on New Document and choose the file importing option: add Synthes large fragment set inventory sheet from your device, the cloud, or a protected URL. Make adjustments to the template. Utilize the top and left panel tools to modify Synthes large fragment set inventory sheet.

Get the Synthes wrist fusion inventory control form accomplished. Download your updated document, export it to the cloud, print it from the editor, or share it with others through a Shareable link or as an email attachment. ... stryker wrist fusion plate 319.01 synthes synthes small frag inventory. Related forms. 18448988542. Learn more ...

The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)Manufacturers attempt to produce enough products to keep the status of their inventory static or unchanging. Whether they produce too much product, meaning their inventory grows --...The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant.Follow our easy steps to get your Synthes Small Frag Inventory prepared rapidly: Pick the web sample from the library. Complete all necessary information in the required fillable areas. The easy-to-use drag&drop user interface makes it easy to add or relocate areas. Make sure everything is completed appropriately, without any typos or lacking ...DePuy Synthes Sets. • Reverse-cutting flutes assist in screw removal. • Choice of thread lengths offers best fit of threads into far bone fragment, for greater interfragmentary compression. • Cancellous thread profile uses deep cutting threads with a large pitch to increase resistance to pullout. The large pitch also acceleratesSynthes Large Fragment LCP Instrument Set 115.401: Manufacturer: Synthes: Mfg. Catalog # 115.401: ... Sell your extra product inventory to Zgrum.com! We are interested in purchasing your in-date, short dated and expired products in full selling units, open boxes and individual items.01.120.457 LCP Large Fragment Instruments and Standard Instruments in Vario Case Plate sets 01.120.332 LCP-DF 4.5/5.0 (Stainless Steel), in Modular Tray, Vario Case System or 01.120.334 LCP-DF 4.5/5.0 (Titanium Alloy/TAN), in Modular Tray, Vario Case System Note on long plates: The LCP DF plates with 15 to 19 holes are available inPlates for the Small Fragment LCP. ®System. (continued) LCP®One-Third Tubular Plates, with collar*. • Available with 3–10 holes (33 mm–117 mm lengths) and 12 holes (141 mm) • Plate contains only locking holes, that accept 3.5 mm locking screws, 3.5 mm cortex screws, and 2.7 mm cortex screws.• Small Fragment Standard Instrument Set (103.501) • Small Fragment Standard Screw Set ... • Large core diameter provides improved bending and shear strength ... Screws Bibliography: 1. DePuy Synthes StarDrive vs Hex Static Torsion Test. 2011. #SET_20110610. Screw Reference Chart Thread Diameter 2.7 mm 3.5 mm 4.0 mm Screw Type Cortex ...Get the Synthes Small Fragment Set Inventory Sheet you want. Open it using the cloud-based editor and start altering. Fill the blank fields; concerned parties names, addresses and numbers etc. Customize the blanks with exclusive fillable fields. Put the day/time and place your electronic signature. Click Done after double-checking all the data.510 (k) Number. K160553. Device Name. DePuy Synthes 4.0 mm and 5.0 mm Locking Screws - MR Conditional, DePuy Synthes Wrist Fusion Plate (WFP) - MR Conditional, DePuy Synthes Large Fragment Dynamic Compression Locking (DCL) System -MR Conditional, DePuy Synthes Small Fragment Dynamic Compression Locking (DCL) System - MR Conditional, De.Related to synthes small frag inventory control form Return form and check to Trike Relay Race Return form and check to Asheville Civic Center, 404 N. Main St. Forms due back by Tuesday, May 3, 2016, Trike Relay Race Teams will need to be at the

2 DePuy Synthes 2.4 mm Variable Angle LCP ® Dorsal Distal Radius Plate Surgical Technique. 2.4 mm Variable Angle LCP ® Dorsal Distal Radius Plate. For fragment-specific fixation with variable angle (VA) locking technology. The low-profile dorsal distal radius plates are intended for the double-plate technique. All implants are available inThe prep of legal paperwork can be expensive and time-consuming. However, with our predesigned online templates, things get simpler. Now, working with a Synthes Medial Distal Tibia Plate Inventory Control Form takes no more than 5 minutes. Our state-specific browser-based samples and clear guidelines eliminate human-prone faults.Get the Synthes Large Frag Inventory you need. Open it using the online editor and begin altering. Complete the blank areas; concerned parties names, places of residence and phone numbers etc. Change the blanks with smart fillable areas. Add the date and place your e-signature. Click Done after double-checking everything.Synthes Large Fragment LCP Instrument Set (115.401) Instrumentation Catalog # Description ... 690.363 Large Fragment LCP Instrument Graphic Case 690.363.10 Base 690.363.11 Lid 690.363.20 Base Tray 292.656 2.0 mm Non-Threaded Guide Wire, Spade Point, 230 mm (4) Author:Instagram:https://instagram. joe cross recent picturessilhouette ford truck clipartoakland dmvlandmark e street cinema reviews Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ... jailbase south bendpoem for retiring principal Complete Synthes Small Frag Lcp Inventory Control Formular online are US Legal Forms. Slightly fill out PDF vacuous, edit, and sign them. Save or promptly senden your ready documents. We use cookies to improve security, personalize the end adventure, enhance our marketing activities (including collaborate with our sell partners) and for other ... hey google set alarm for 5 30 Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...The Mini Fragment System (or "Mini Frag") is designed to aid in the reduction and fixation of small and long bone trauma injuries. The tray modularity offers screw and plate options in 2.0 mm, 2.4 mm, and 2.7 mm sizes. With a wide array of plates to fit a multitude of trauma needs, the Mini Fragment System is a keystone addition to the Arthrex Trauma portfolio. Features and Benefits ...