How to read trane model number.

An A/C’s SEER rating is also listed near the top of the unit’s manufacturer label, where the model and serial number are listed. Look for the beginning digits of the model number. For example, a model number that begins with 15AC means the air conditioner has a SEER rating of 15.

How to read trane model number. Things To Know About How to read trane model number.

Buying a HDTV is hard enough with so many different manufactures, model numbers, and sizes, to make things a little easier we've put together a list of the most common specificatio...4 days ago · Most model numbers begin with the series or equipment type. Consider the EL in this model number as a code name for a group of similar equipment. These letters or numbers group equipment into categories such as furnaces or air handlers. Condensing units, heat pumps, cooling or heating coils, and package units also follow this pattern. This "How to Locate Your Furnace Model and Serial Number" video guides the viewer through how to find, identify and use the information on the manufacturer data sticker to determine the series, model and revision information necessary for ordering the correct furnace parts your particular furnace at HvacPartsShop.com. The information is crucial ... 4TTZ0048A1000AA is a Trane 48,000 BTU or 4 ton system If you are unable to read the label you can look down into the condensing unit from the top to see the compressor and often use the compressor part number to determine the tonnage using Google. Age: The age is generally encoded into the serial number. About This Manual. This manual describes the installation of with recommended wiring, piping, and mounting of single-duct, dual-duct, fan-powered, and low-height VAV terminal units, and chilled water sensible coil terminal units. See also the following reference documents: BAS-SVX40-EN —Wireless Comm IOM.

First letter: The model number starts with 4. Second letter. The next 3 letter represents the product type. The fifth number is for unit’s Seasonal Energy Efficiency Ratio. The six letter. The seven and eight number indicate tonnage. The nine letter represents the age.

Benzinga reviews this weekend's top stories covered by Barron's, here are the articles investors need to read. In "Roku Earnings Fli... Benzinga reviews this weekend'...Read's approach to having a TikTok-style short video summary can appeal to people looking to skim through multiple missed meetings. Summarization is one of the common use cases of ...

CRN The Canadian Registration Number, or CRN, is given to companies that comply with Canada’s Technical Safety Standards Act concer ning pressure vessel safety. In Trane air-handling systems, the CRN applies to coils classified as Category H fittings. Most government and industrial customers require the HVAC supplier to have a CRN. Trane has If you've misplaced the manuals, the Carrier model and serial numbers are usually on the unit itself, often at the back or inside the outdoor unit’s metal door. Look for a rating plate sticker on the top left; it should display both the model and serial number. Watch this short video for more details.The display screen on the remote controller displays “SE”. Repeat the operation to quit the function. Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 8℃ Heating . on the remote controller displays“ ” and a selected temperature of “ 8℃(46°F)” (46 if Fahrenheit is adopted). Repeat the operation to quit the ...The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. Model Family (Nominal Efficiency) 80 = 80% Non-Condensing 95 = 95% + Condensing Blower Type P = PSC Motor X = Constant Torque Motor V = Variable Speed Motor BTU Input (Nominal Heating Capacity) BTU/Hour x 1000 Type S = Standard system T = 40ng/J NOx L = 14 ng/J NOx Cabinet Width A = 14.5” B = 17.5” C = 21” D = 24.5” Orientation

Post Likes. Originally Posted by rundawg. Your YSC036 A design sequence (first sequence) was manufactured from about 2001 - 2007. Serial Number - 7 23 102719L. I found where the ship date of this unit was 7 / 2007. So i'm going to jump into Elizeze camp, and say the reference he posted is correct.

When it comes to choosing a new air conditioner for your home, there are many factors to consider. Energy efficiency, reliability, and performance are just a few of the important a...

This video shows how to tell the age and size of your Trane equipment. It also shows you what type of refrigerant the unit uses if it is R-22 or R-410A. Usua... Model Number Coding System The model numbers for the un it and the compressors are comprised of numbers and letter which represent features of the equipment. See “Unit Model Number Description,” p. 8 and “Compressor Model Number Description,” p. 9 for details. Each position, or group of positions, in a number or letter Table 1. Model number description T*D Cooling Only (Electric Heat Optional), Downflow T*H Cooling Only (Electric Heat Optional), Horizontal Y*D Gas Heat Unit, Downflow Y*H Gas Heat Unit, Horizontal * Standard (S) or High (H) Efficiency Table 2. List of factory installed options (FIOPs)(a)Re: Trane Water chiller model number. Thanks for the prompt replies. I got onto someone from Trane in Asia who sent me a brochure on the unit. The 040 could possibly be related to 40 tons @ 60hz running at 25 degree C ambient, thats about as close as it gets. Thanks again. This video shows how to tell the age and size of your Trane Air Handler. It also shows you what type of refrigerant the unit uses if it is R-22 or R-410A. Us... CRN The Canadian Registration Number, or CRN, is given to companies that comply with Canada’s Technical Safety Standards Act concer ning pressure vessel safety. In Trane air-handling systems, the CRN applies to coils classified as Category H fittings. Most government and industrial customers require the HVAC supplier to have a CRN. Trane has

i own a trane xe 80 model number tud100c93680 and i want to match it with a trane a/c, what a/c should i buy for a 3 ton or 4 ton unit. and what is the fan cfm, thanks. steven … read more BillyHvacDECODING OF MANUFACTURER MODEL NUMBERS. The Department used manufacturer model numbers, among other furnace characteristics, to determine … Can anyone please tell me what these model numbers mean or where I can uncode them, thanks. Evaporator Coil: 4NXCB025AC. 4TXCA025BC3HCA. Reply. 02-05-2015, 11:21 PM #2. Manuals/Application Guides/Literature. Follow. LCU Voyager Modulating gas heat manuals. Light Commercial Power Burner troubleshooting Guide. Eflex troubleshooting manuals. Wiring Manuals for R22 Precedent Units. Zoned Rooftop Systems Catalog.Trane RTAF Series Unit Model Number Nomenclature (Typical Model Number Example) Digits 1, 2 - Unit Model RT = Rotary Chiller Digit 3 - Unit Type A= Air-cooled Digit 4 - Development Sequence F = Development Sequence Digits 5, 6, 7 - Nominal Capacity 115 = 115 Nominal Tons 130 = 130 Nominal Tons 150 = 150 Nominal Tons 170 = 170 …IBIO stock will go through peaks and valleys, but it's still a spec play lacking fundamental strength. Day traders should have fun, though. Covid-19 is pushing iBio stock to unprec...The number of machine learning (ML) and artificial intelligence (AI) models published in clinical research is increasing yearly. Whether clinicians choose to dive deep into the mat...

Manuals/Application Guides/Literature. Follow. LCU Voyager Modulating gas heat manuals. Light Commercial Power Burner troubleshooting Guide. Eflex troubleshooting manuals. Wiring Manuals for R22 Precedent Units.How do you read Trane nomenclature? Trane Model Number Location. First letter. Second letter. The third letter represents the product type. The fourth letter equals the product family. The fifth number is for unit’s Seasonal Energy Efficiency Ratio. The six letter. The seven and eight number indicate size in tonnage.

Step 1. Look at the first number on the outside unit's model number. The model number starts with a two or four. This number represents the type of refrigerant the system uses. Two stands for R-22 and four stands for R410A. Video of the Day. Step 2. Notice the next three letters. T stands for Trane. The following letter represents the product type.Apr 19, 2020 · The serial number should start with one to two numbers. These numbers indicate the year that your furnace was manufactured. For example, a two indicates that the furnace was made in the year 2002. A four would indicate that the unit was made in 2004. Typically, the following number would not make sense as a double-digit year. Trane is a renowned name in the HVAC industry, known for its high-quality and reliable heating and cooling products. When it comes to furnaces, Trane offers a wide range of models ... Static Pressure Transducer output voltage at RTAM J1-3 is less than 0.25VDC. The transducer output is open, shorted, or the transducer is reading a negative supply air pressure. HEAT + COOL + SERVICE. Static Pressure High Duct Static Trip. The static pressure has exceeded 3.5" W.C. three consecutive times. Ground wire on transducer is open. Let’s say that the serial number is #1E-123456 (it was used in the 1970s), where one is 1971, and E is May. Serial Number #P16-12ABCD (Trane used it in 1983)- P is the year (1999), whereas 16 is the week. Serial Number #03161-ABCDE (Trane used the system between 2002 and 2009). 03 represents the year (2003), 16 represents the week, and 1 is ... The model number will not tell you the age, it should be on the tag. The age can be determined by the serial number. If it is installed with ductboard, look at the date on the tape, if they used fresh tape, that is one indication of age. Reply. 07-01-2010, 12:52 PM #10.Static Pressure Transducer output voltage at RTAM J1-3 is less than 0.25VDC. The transducer output is open, shorted, or the transducer is reading a negative supply air pressure. HEAT + COOL + SERVICE. Static Pressure High Duct Static Trip. The static pressure has exceeded 3.5" W.C. three consecutive times. Ground wire on transducer is open.Serial Number 19 34 6 0205 J 19: year of 2019 34: 34th week of the calendar year 6: 6th day of that week (1 = Monday, 2 = Tuesday… 6 = Saturday) 0205: the 205th unit Search for the data tag or sticker plate on the unit. You will find all the detailed information for your unit in the data tag. Thanks to the data tag, the serial number, model number, ANSI rating, etc., will be found out. Here’s where you will find the manufacture date, depending on the Trane product you purchased:

Here is an example of a Trane brand air conditioner and how to use its air conditioner model decoder: How Do I Read My AC Model Number? Let's look at a Trane brand air conditioner as an example. Capacity: Trane has used a number of different methods for encoding capacity information in the model number. It is commonly found in the first …

The serial number should start with one to two numbers. These numbers indicate the year that your furnace was manufactured. For example, a two indicates that the furnace was made in the year 2002. A four would indicate that the unit was made in 2004. Typically, the following number would not make sense as a double-digit year.

Re: Trane Water chiller model number. Thanks for the prompt replies. I got onto someone from Trane in Asia who sent me a brochure on the unit. The 040 could possibly be related to 40 tons @ 60hz running at 25 degree C ambient, thats about as close as it gets. Thanks again.Here is an example of a Trane brand air conditioner and how to use its air conditioner model decoder: How Do I Read My AC Model Number? Let's look at a Trane brand air conditioner as an example. Capacity: Trane has used a number of different methods for encoding capacity information in the model number. It is commonly found in the first …System Reference Guide CITY MULTI® Outdoor Unit Model Number Reference Guide Note: Branch circuit controller required. • NTX (Heat Pump) • NTY (Cooling Only) • …HVAC BRAND MODEL NUMBER NOMENCLATURE. Select one of the drop-down lists below. that corresponds to the FIRST letter. of your HVAC brand name. Then make your selection from the list. HVAC - A. HVAC - B. HVAC - C. HVAC - D.Model Number Coding System The model numbers for the un it and the compressors are comprised of numbers and letter which represent features of the equipment. See “Unit Model Number Description,” p. 8 and “Compressor Model Number Description,” p. 9 for details. Each position, or group of positions, in a number or letterTrane Tonnage. Trane is the only brand we are familiar with that occasionally lists a two-digit number for the thousands of BTU rating that is not divisible by 6 or 12—but close. Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons.How to read AC model number? The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 …Feb 15, 2023 ... Low Ambient Control Model Number: Used With: FIALOAM001 6 to 25 tons with Symbio™ controls Introduction Read this manual...Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. Trane and American Standard create comfortable, energy efficient indoor environments for

Look for a number that is divisible by 6 or 12 somewhere in the center of the model number on the data plate at the side of the heat pump condenser (outdoor unit), like 12,18, 24, 30, 36, 42, 48, or 60. A ton of air conditioning equals 12,000 BTU's so, for example a “24” in the middle of the model number indicates that it is a 2-ton system ...environment. Trane advocates the responsible handling of all refrigerants-including industry replacements for CFCs and HCFCs such as saturated or unsaturated HFCs and HCFCs. Important Responsible Refrigerant Practices Trane believes that responsible refrigerant practices are important to the environment, our customers, and the airLook for a number that is divisible by 6 or 12 somewhere in the center of the model number on the data plate at the side of the heat pump condenser (outdoor unit), like 12,18, 24, 30, 36, 42, 48, or 60. A ton of air conditioning equals 12,000 BTU's so, for example a “24” in the middle of the model number indicates that it is a 2-ton system ...Instagram:https://instagram. how much kinetic energy to kill a deermidnight gladness shady maple 2023matthew podolak obituarydriver license office tampa fl How do you read Trane nomenclature? Trane Model Number Location. First letter. Second letter. The third letter represents the product type. The fourth letter equals the product family. The fifth number is for unit’s Seasonal Energy Efficiency Ratio. The six letter. The seven and eight number indicate size in tonnage. craigslist boise apartmentsmarysville wa theater Unit Description. The CGAM units are scroll type, air-cooled, liquid chillers, designed for installation outdoors. The 20 to 35 ton units have a single independent refrigerant circuit, with two compressors per circuit. The 40 ton and larger units have 2 independent refrigerant circuits, with two compressors per circuit. joannes manchester ct My Trane model # is: TTP018C100A2 and my serial number is: L26340Kff. Any help would be greatly appreciated!!! Last edited by beenthere; 06-10-2009 at 08:23 PM . Reason: Removed price.How do you read Trane nomenclature? Trane Model Number Location. First letter. Second letter. The third letter represents the product type. The fourth letter equals the product family. The fifth number is for unit’s Seasonal Energy Efficiency Ratio. The six letter. The seven and eight number indicate size in tonnage.Trane RTAF Series Unit Model Number Nomenclature (Typical Model Number Example) Digits 1, 2 - Unit Model RT = Rotary Chiller Digit 3 - Unit Type A= Air-cooled Digit 4 - Development Sequence F = Development Sequence Digits 5, 6, 7 - Nominal Capacity 115 = 115 Nominal Tons 130 = 130 Nominal Tons 150 = 150 Nominal Tons 170 = 170 …